Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
AICr

Regulatory Identifiers

CAS Number
N/A
UFI Code
not required

Identified Uses

Metallurgical industry, additive to casting alloy

Uses advised against

Other then listed in section 1.2.1.

Manufacturers & Suppliers

Alumetal Poland Sp. z o. o. Zakład Gorzyce logo

Alumetal Poland Sp. z o. o. Zakład Gorzyce

manufacturer

ul. Odlewników 52, 39-432 Gorzyce, Poland

+48 15 644 94 00

http://www.alumetal.pl

Emergency Contacts

producer

+48 15644 94 00

7:00 – 15:00

emergency centre

112

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

The product is a mixture – alloy of aluminium and chromium

Chemical Name CAS Number Concentration Hazardous
Aluminium EC: 231-072-3 7429-90-5 78 - 96% No
Chromium EC: 231-157-5 7440-47-3 4 - 22% No

Notes

The classification of hazardous substances contained in the product is given in Table 3 of Annex VI to the Regulation of the European Parliament and Council Regulation (EC) No 1272/2008 including its amends, REACH data, the manufacturer and available literature data.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move victim to fresh air. If symptoms persist, consult a doctor. If breathing is difficult, give oxygen, in the absence of breath use artificial respiration. Seek medical advice immediately.

Symptoms: Irritation of eyes, nose and throat. Metallic taste in the mouth, dryness and irritation of the throat, chills and fever.

Skin contact

In case of burns immediately cool the skin, apply dressing contact with doctor. In case of skin injury by sharp edges, clean, disinfect and dress the wound, if necessary, contact with doctor. In the case of persistent irritation consult a dermatologist.

Symptoms: Burns, skin injury by sharp edges.

Eye contact

Rinse eyes with running water with wide-open eyelids, a continuous stream of water for about 10 minutes. In the case of persistent irritation consult an ophthalmologist.

Symptoms: Irritation by fumes or dust.

Ingestion

Not applicable

Immediate Medical Attention

In the event of health problems, immediately contact doctor. Seek medical advice immediately for inhalation.

Medical Treatment

No specific antidote, treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use powder extinguishing agents for metals. If they are not available, just use dry sand.

Unsuitable media

Do not use a direct stream of water – risk of explosion of steam, halogenated compounds

Specific hazards

Thermal decomposition of the product may produce harmful smoke and gases. Avoid inhalation of combustion products, may pose a threat to health. Product in handling form is not flammable. Danger creates fine particles of product which may accumulate when working in dry conditions, or in the presence of oil mist. Dust the product are rapidly burning in fire. Form explosive mixtures in air. After igniting the material is virtually impossible to extinguish. Fire-fighting action should be limited to isolate the burning material, for example by covering with sand or cement and prevent the spread of fire. Melted product reacts violently with water, can cause an explosion.

Instructions

Fire-fighting action should be limited to isolate the burning material, for example by covering with sand or cement and prevent the spread of fire.

Firefighter Protection

Strictly apply the breathing apparatus and protective clothing for fire fighting or during clean-up work immediately after a fire in an enclosed or poorly ventilated areas.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

In case of release of the product, move damaged packaging of the product into an empty container. Released product gather in closed container for disposal or reuse.

Environmental

Do not allow to enter drains, groundwater, soil and open water courses.

Cleanup methods

Released product gather in closed container for disposal or reuse.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid contact with eyes and skin, breathing dust of product created by cutting, sanding operation with product. Use personal protective equipment. Ensure adequate ventilation/exhaust in the workplace, prevent the formation of harmful concentrations of dust in the air, work in well ventilated areas. Observe good personal hygiene and wear protective clothing in accordance with information set out in section 8. Do not touch or move the castings of aluminium or hot materials before checking their temperature. Aluminium does not change colour when heated.

Storage

Store product in dry storage rooms. Keep away from sources of heat and fire.

Hygiene

Observe good personal hygiene and wear protective clothing. Ensure place for eyes and skin rinsing, provide easy access to running water, wash hands with soap and water before eating, smoking and after work, use general caution while working with chemical substances.

Fire prevention

Store and use the product while ensuring adequate ventilation away from potential ignition sources like open fire.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Use engineering controls to reduce air contamination to permissible exposure level. Explosion-proof general and local exhaust ventilation. Monitor exposure and apply all possible technical measures to ensure the maintenance of the concentrations of hazardous products in the workplace below recommended exposure limits.

Hands

Recommended protective gloves. Standards: EN ISO 21420:2020, EN ISO 374-1:2017/A1:2018, EN ISO 374-2:2020, EN 16523-1:2015+A1:2018, EN 407:2020.

Eyes

Safety glasses in a sealed cover (goggles) (e.g. EN 166). Standards: EN ISO 16321-1:2022, EN ISO 16321-3:2022, EN ISO 4007:2018.

Respiratory

Not necessary under normal conditions with sufficient ventilation, required during exposure to high concentrations of dust. Wear mask or respirator completed with the antidust filter. Standards: EN 140:1999/AC:2000, EN 143:2021, EN 149:2001+A1:2009.

Skin/Body

Protective, working clothing. Body protection must be chosen depending on activity and possible exposure (according to EN ISO 13982 in case of dust). Standards: EN ISO 13688:2013, EN 14605:2005+A1:2009, EN ISO 20345:2022.

Environmental

Do not allow to enter large amounts of product into ground water, sewage, waste water or soil.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Ph
does not apply
Appearance
---
Physical State
solid, bars
Properties Status
---
Melting Point
not determined
Evaporation Rate
---
Flammability
does not apply
Lower Explosive Limit
does not apply
Dynamic Viscosity
---
Auto Ignition Temperature
does not apply
Molecular Weight
---
Flash Point
does not apply
Cloud Point
---
Kinematic Viscosity
does not apply
Relative Density
not determined
Softening Point
---
Explosive Limits
---
Metal Corrosion
---
Vapor Pressure
does not apply
Bulk Density
---
Colour
grey
Solidification Point
---
Decomposition Temperature
does not apply
Upper Explosive Limit
does not apply
Boiling Point
does not apply
Form
---
Freezing Point
not determined
Vapor Density
---
Solubility In Fat
---
Crystallisation Point
---
Solubility
insoluble in water
Relative Evaporation Rate
---
Voc Content
---
Colour Intensity
---
Partition Coefficient
does not apply
Odor Threshold
---
Odor
no
State Under Standard Conditions
---
Density
not determined
Physical State Data
solid
Solubility In Water
insoluble
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions (see Section 7 – storage conditions)

Reactivity

Not applicable for product in handling form.

Hazardous reactions

No data

Avoid

In the case of dust creation avoid sources of ignition (dusts of aluminium alloys may form explosive mixtures with air). Aluminium castings must be stress-free against possible parting in order to prevent an explosion or a sudden cracking. During the melting of aluminium, aluminium alloy or aluminium scrap, eliminate the possibility of water intrusion. Water or moisture contact with hot or melted metal can cause a violent explosion. During the operation of heating and melting should be eliminated possibility of contact with strong oxidizing agents, to prevent the possibility of explosion.

Incompatible

Product may react with strong acids, alkalis and oxidizing agents to form hydrogen, which is flammable. Contact with chlorine-based solvents can lead to release of toxic and corrosive hydrogen chloride gas. Hot aluminium can react with solvent-based chlorine to form phosgene, a highly toxic and irritating gas.

Decomposition

Under normal conditions of use are not known

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Dispose of waste in accordance with all Federal, State and Local regulations.

Disposal

communicate with the manufacturer of the product on the possibility of processing waste. If it's not possible, deliver it to utilization in plants permitted to waste collection, transport, waste recovery and disposal. Do not empty into drains. Recovery or disposal of waste product should be made in accordance with applicable regulations.

Waste Codes

19 10 02 non-ferrous waste EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Safety, health and environmental regulations/legislation specific for the substance or mixture

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for AICr?

The signal word is no signal word.

What is the physical form of AICr?

AICr is a solid, bars with grey color. It has no odor.

What is the solubility of AICr?

insoluble in water

What is AICr used for?

Metallurgical industry, additive to casting alloy

What is the melting point of AICr?

The melting point is not determined and the boiling point is does not apply.