Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Blitz® II Surgical Instrument Cleaner and Lubricant
Product Code
M105A

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Consult manufacturer for recommended product use.

Manufacturers & Suppliers

C

ConMed Linvatec

manufacturer

Largo, FL 33773, United States

1-800-237-0169

Emergency Contacts

Manufacturer

1-800-424-9300

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Flammable Gases 1
Compressed Gas
Specific Target Organ Toxicity Single Exposure 3: Narcotic Effects
Simple Asphyxiant

GHS Pictograms

GHS02 - Flammable

GHS02

GHS04 - Compressed gas

GHS04

GHS07 - Health hazard

GHS07

Hazard Statements

H220 Extremely flammable gas
H270 May displace oxygen and cause rapid suffocation.
H280 Contains gas under pressure; may explode if heated
H336 May cause drowsiness or dizziness

Precautionary Statements

P210 Keep away from heat, sparks, open flames and/or hot surfaces. - No smoking.
P210 Eliminate all ignition sources if safe to do so.
P233 Keep container tightly closed.
P261 Avoid breathing mist, vapours and/or spray.
P271 Use only outdoors or in a well-ventilated area.
P304 + P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing.
P312 Call a POISON CENTER/doctor if you feel unwell.
P377 Leaking gas fire: Do not extinguish, unless leak can be stopped safely.
P403 Store in a well-ventilated place.
P405 Store locked up.
P410 Protect from sunlight.
P501 Dispose of content and/or container in accordance with local, regional, national, and/or international regulations.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Heavy alkylate (petroleum) naphtha 64741-65-7 63% Yes
Propane 74-98-6 13% Yes
Butane 106-97-8 13% Yes
Mineral oil, petroleum distillates, solvent -dewaxed heavy paraffinic (mild or nosolvent-refining or hydrotreatment) 64742-65-0 11% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove victim to fresh air and keep at rest in a position comfortable for breathing. Administer oxygen if breathing is difficult. Give artificial respiration if victim is not breathing. If signs/symptoms continue, get medical attention.

Skin contact

In case of contact with substance, immediately flush skin with running water for at least 20 minutes.

Eye contact

In case of contact with substance, immediately flush eyes with running water for at least 20 minutes.

Ingestion

Do NOT induce vomiting. Get medical attention.

Immediate Medical Attention

Get medical attention.

Medical Treatment

All treatments should be based on observed signs and symptoms of distress in the patient. Consideration should be given to the possibility that overexposure to materials other than this product may have occurred.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

SMALL FIRES: Dry chemical or CO2. LARGE FIRES: Water spray or fog.

Unsuitable media

No data available

Specific hazards

EXTREMELY FLAMMABLE. Will form explosive mixtures with air. Vapors may travel to source of ignition and flash back. Cylinders exposed to fire may vent and release flammable gas through pressure relief devices. Containers may explode when heated. Ruptured cylinders may rocket.

Instructions

DO NOT EXTINGUISH A LEAKING GAS FIRE UNLESS LEAK CAN BE STOPPED. Move containers from fire area if you can do it without risk. FIRE INVOLVING TANKS: ALWAYS stay away from tanks engulfed in fire. Fight fire from maximum distance or use unmanned hose holders or monitor nozzles. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. Cool containers with flooding quantities of water until well after fire is out. Do not direct water at source of leak or safety devices; icing may occur. For massive fire, use unmanned hose holders or monitor nozzles; if this is impossible, withdraw from area and let fire burn.

Firefighter Protection

Structural firefighters' protective clothing provides limited protection in fire situations ONLY; it is not effective in spill situations where direct contact with the substance is possible. Always wear thermal protective clothing when handling refrigerated/cryogenic liquids. Wear positive pressure self-contained breathing apparatus (SCBA).

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

ELIMINATE all ignition sources (no smoking, flares, sparks or flames in immediate area). As an immediate precautionary measure, isolate spill or leak area for at least 100 meters (330 feet) in all directions. Keep unauthorized personnel away. Keep out of low areas. Stay upwind.

Large spill

Consider initial downwind evacuation for at least 800 meters (1/2 mile)

Environmental

Prevent spreading of vapors through sewers, ventilation systems and confined areas.

Cleanup methods

Isolate area until gas has dispersed.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Use only with adequate ventilation. Keep away from heat and ignition sources – No Smoking. Take precautionary measures against static charges. Use only non-sparking tools. All equipment used when handling the product must be grounded. Wear appropriate personal protective equipment, avoid direct contact. Avoid breathing mist, vapours and/or spray. Be aware of any signs of dizziness or fatigue, especially if work is done in a poorly ventilated area; exposures to fatal concentrations of this gas mixture could occur without any significant warning symptoms, due to olfactory fatigue or oxygen deficiency. Wash thoroughly after handling. Empty containers retain product residue and can be hazardous. Do not cut, weld, puncture or incinerate container.

Storage

Store in a cool, dry, well-ventilated place.

Hygiene

Wash thoroughly after handling.

Fire prevention

Keep away from heat and ignition sources – No Smoking. Take precautionary measures against static charges. Use only non-sparking tools.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Aerosol
Physical State Data
aerosol
State Under Standard Conditions
---
Appearance
Aerosol
Colour
No data available
Colour Intensity
---
Form
---
Odor
No data available
Odor Threshold
No data available
Ph
No data available
Melting Point
No data available
Boiling Point
0 to 412 °F(-17.7778 to 211.1111 °C)
Flash Point
< 0 °F(< -17.7778 °C)
Freezing Point
No data available
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
> 1 Ether = 1
Vapor Pressure
No data available
Vapor Density
> 1 Air=1
Relative Density
= 0.69 Water=1
Bulk Density
---
Density
---
Flammability
---
Upper Explosive Limit
No data available
Lower Explosive Limit
No data available
Explosive Limits
---
Auto Ignition Temperature
No data available
Decomposition Temperature
No data available
Solubility
---
Partition Coefficient
---
Solubility In Water
No data available
Solubility In Fat
---
Molecular Weight
---
Voc Content
88.89 % Less Water and Federally Exempt Solvents
Metal Corrosion
---
Dynamic Viscosity
No data available
Kinematic Viscosity
No data available
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal temperatures and pressures.

Reactivity

No dangerous reaction known under conditions of normal use.

Hazardous reactions

Hazardous polymerization will not occur.

Avoid

Keep away from heat, sparks and flame.

Incompatible

None known.

Decomposition

By fire: Carbon Dioxide, Carbon Monoxide.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN1950
Shipping Name
Aerosols
Transport Class
2.1
Packing Group
Not Applicable
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Blitz® II Surgical Instrument Cleaner and Lubricant?

The signal word is danger.

What is the physical form of Blitz® II Surgical Instrument Cleaner and Lubricant?

Blitz® II Surgical Instrument Cleaner and Lubricant is a aerosol appearing as aerosol with no data available color. It has no data available odor.

What is Blitz® II Surgical Instrument Cleaner and Lubricant used for?

Consult manufacturer for recommended product use.

What are the hazard statements for Blitz® II Surgical Instrument Cleaner and Lubricant?

This substance has 4 hazard statements:

  • H220: Extremely flammable gas
  • H270: May displace oxygen and cause rapid suffocation.
  • H280: Contains gas under pressure; may explode if heated
  • H336: May cause drowsiness or dizziness

What is the melting point of Blitz® II Surgical Instrument Cleaner and Lubricant?

The melting point is No data available and the boiling point is 0 to 412 °F(-17.7778 to 211.1111 °C).