Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Blitz® II Surgical Instrument Cleaner and Lubricant
- Product Code
- M105A
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Consult manufacturer for recommended product use.
Manufacturers & Suppliers
ConMed Linvatec
manufacturer
Largo, FL 33773, United States
1-800-237-0169
Emergency Contacts
Manufacturer
1-800-424-9300
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS04
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Heavy alkylate (petroleum) naphtha | 64741-65-7 | 63% | Yes |
| Propane | 74-98-6 | 13% | Yes |
| Butane | 106-97-8 | 13% | Yes |
| Mineral oil, petroleum distillates, solvent -dewaxed heavy paraffinic (mild or nosolvent-refining or hydrotreatment) | 64742-65-0 | 11% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove victim to fresh air and keep at rest in a position comfortable for breathing. Administer oxygen if breathing is difficult. Give artificial respiration if victim is not breathing. If signs/symptoms continue, get medical attention.
In case of contact with substance, immediately flush skin with running water for at least 20 minutes.
In case of contact with substance, immediately flush eyes with running water for at least 20 minutes.
Do NOT induce vomiting. Get medical attention.
Immediate Medical Attention
Get medical attention.
Medical Treatment
All treatments should be based on observed signs and symptoms of distress in the patient. Consideration should be given to the possibility that overexposure to materials other than this product may have occurred.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
SMALL FIRES: Dry chemical or CO2. LARGE FIRES: Water spray or fog.
No data available
EXTREMELY FLAMMABLE. Will form explosive mixtures with air. Vapors may travel to source of ignition and flash back. Cylinders exposed to fire may vent and release flammable gas through pressure relief devices. Containers may explode when heated. Ruptured cylinders may rocket.
DO NOT EXTINGUISH A LEAKING GAS FIRE UNLESS LEAK CAN BE STOPPED. Move containers from fire area if you can do it without risk. FIRE INVOLVING TANKS: ALWAYS stay away from tanks engulfed in fire. Fight fire from maximum distance or use unmanned hose holders or monitor nozzles. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. Cool containers with flooding quantities of water until well after fire is out. Do not direct water at source of leak or safety devices; icing may occur. For massive fire, use unmanned hose holders or monitor nozzles; if this is impossible, withdraw from area and let fire burn.
Firefighter Protection
Structural firefighters' protective clothing provides limited protection in fire situations ONLY; it is not effective in spill situations where direct contact with the substance is possible. Always wear thermal protective clothing when handling refrigerated/cryogenic liquids. Wear positive pressure self-contained breathing apparatus (SCBA).
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
ELIMINATE all ignition sources (no smoking, flares, sparks or flames in immediate area). As an immediate precautionary measure, isolate spill or leak area for at least 100 meters (330 feet) in all directions. Keep unauthorized personnel away. Keep out of low areas. Stay upwind.
Consider initial downwind evacuation for at least 800 meters (1/2 mile)
Prevent spreading of vapors through sewers, ventilation systems and confined areas.
Isolate area until gas has dispersed.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Use only with adequate ventilation. Keep away from heat and ignition sources – No Smoking. Take precautionary measures against static charges. Use only non-sparking tools. All equipment used when handling the product must be grounded. Wear appropriate personal protective equipment, avoid direct contact. Avoid breathing mist, vapours and/or spray. Be aware of any signs of dizziness or fatigue, especially if work is done in a poorly ventilated area; exposures to fatal concentrations of this gas mixture could occur without any significant warning symptoms, due to olfactory fatigue or oxygen deficiency. Wash thoroughly after handling. Empty containers retain product residue and can be hazardous. Do not cut, weld, puncture or incinerate container.
Store in a cool, dry, well-ventilated place.
Wash thoroughly after handling.
Keep away from heat and ignition sources – No Smoking. Take precautionary measures against static charges. Use only non-sparking tools.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal temperatures and pressures.
No dangerous reaction known under conditions of normal use.
Hazardous polymerization will not occur.
Keep away from heat, sparks and flame.
None known.
By fire: Carbon Dioxide, Carbon Monoxide.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN1950
- Shipping Name
- Aerosols
- Transport Class
- 2.1
- Packing Group
- Not Applicable
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Blitz® II Surgical Instrument Cleaner and Lubricant?
The signal word is danger.
What is the physical form of Blitz® II Surgical Instrument Cleaner and Lubricant?
Blitz® II Surgical Instrument Cleaner and Lubricant is a aerosol appearing as aerosol with no data available color. It has no data available odor.
What is Blitz® II Surgical Instrument Cleaner and Lubricant used for?
Consult manufacturer for recommended product use.
What are the hazard statements for Blitz® II Surgical Instrument Cleaner and Lubricant?
This substance has 4 hazard statements:
- H220: Extremely flammable gas
- H270: May displace oxygen and cause rapid suffocation.
- H280: Contains gas under pressure; may explode if heated
- H336: May cause drowsiness or dizziness
What is the melting point of Blitz® II Surgical Instrument Cleaner and Lubricant?
The melting point is No data available and the boiling point is 0 to 412 °F(-17.7778 to 211.1111 °C).