NextSDS Logo
Safety Data Sheet EN

INDUCARE DRY CLEAN

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
INDUCARE DRY CLEAN

Regulatory Identifiers

CAS Number
N/A
REACH No.
Not applicable (mixture)

Identified Uses

Detergent according to Regulation (EC) No 648/2004

Uses advised against

No uses advised against known

Manufacturers & Suppliers

N

Novatio

national supplier

Industrielaan 5B, B-2250 Olen

+32 14 25 76 40

N

Novatech International N.V.

manufacturer

Industrielaan 5B, B-2250 Olen

+32 14 85 97 37

Emergency Contacts

BIG

+32 14 58 45 45

24h/24h

EN, FR, DE, NL

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
ethanol EC: 200-578-6 64-17-5 5% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove the victim into fresh air. Respiratory problems: consult a doctor/medical service.

Symptoms: No effects known.

Skin contact

Rinse with water. Take victim to a doctor if irritation persists.

Symptoms: No effects known.

Eye contact

Rinse with water. Take victim to an ophthalmologist if irritation persists.

Symptoms: No effects known.

Ingestion

Rinse mouth with water. Consult a doctor/medical service if you feel unwell.

Symptoms: No effects known.

Immediate Medical Attention

If applicable and available it will be listed below.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray. Polyvalent foam. Dry chemical powder. Carbon dioxide.

Unsuitable media

No unsuitable extinguishing media known.

Specific hazards

Upon combustion CO and CO2 are formed (carbon monoxide - carbon dioxide).

Instructions

No specific fire-fighting instructions required.

Firefighter Protection

Gloves. Protective clothing. Heat/fire exposure: compressed air/oxygen apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Contain released product.

Cleanup methods

Take up liquid spill into absorbent material. Scoop absorbed substance into closing containers. Clean contaminated surfaces with an excess of water. Wash clothing and equipment after handling.

Materials: absorbent material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Keep away from naked flames/heat. Observe normal hygiene standards. Keep container tightly closed.

Storage

Storage temperature: <50 °C. Keep container in a well-ventilated place. Protect against frost. Keep out of direct sunlight. Meet the legal requirements.

Hygiene

Observe normal hygiene standards.

Fire prevention

Keep away from naked flames/heat.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Keep away from naked flames/heat. Measure the concentration in the air regularly. Carry operations in the open/under local exhaust/ventilation or with respiratory protection.

Hands

Gloves. Materials: viton, Breakthrough time: >480 minutes, Thickness: 0.35 mm. - materials (good resistance) Viton.

Eyes

Eye protection not required in normal conditions.

Respiratory

Wear gas mask with filter type A if conc. in air > exposure limit.

Environmental

See headings 6.2, 6.3 and 13

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
No data available on colour
Colour Intensity
---
Form
---
Odor
Characteristic odour
Odor Threshold
No data available
Ph
7.0
Melting Point
0 °C
Boiling Point
78 °C
Flash Point
No data available
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
2.00 ; butyl acetate
Vapor Pressure
23.3 hPa ; 20 °C
Vapor Density
---
Relative Density
1.0 ; 20 °C
Bulk Density
---
Density
1000 kg/m³ ; 20 °C
Flammability
Non-flammable
Upper Explosive Limit
No data available
Lower Explosive Limit
No data available
Explosive Limits
---
Auto Ignition Temperature
No data available
Decomposition Temperature
No data available
Solubility
---
Partition Coefficient
Not applicable (mixture)
Solubility In Water
insoluble
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
50 mPa.s; 20 °C
Kinematic Viscosity
50 mm²/s; 20 °C
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

Substance has neutral reaction.

Hazardous reactions

No data available.

Avoid

Keep away from naked flames/heat.

Incompatible

Oxidizing agents, reducing agents, (strong) acids, (strong) bases.

Decomposition

Upon combustion CO and CO₂ are formed (carbon monoxide - carbon dioxide).

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Treat using the best available techniques before discharge into drains or the aquatic environment.

Disposal

Remove waste in accordance with local and/or national regulations.

Waste Codes

20 01 30 separately collected fractions (except 15 01): detergents other than those mentioned in 20 01 29 EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

No chemical safety assessment is required for the mixture, but a chemical safety assessment has been performed for ethanol.

Chemical Safety Assessment Performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for INDUCARE DRY CLEAN?

The signal word is no signal word.

What is the physical form of INDUCARE DRY CLEAN?

INDUCARE DRY CLEAN is a liquid with no data available on colour color. It has characteristic odour odor.

What is INDUCARE DRY CLEAN used for?

Detergent according to Regulation (EC) No 648/2004

What is the melting point of INDUCARE DRY CLEAN?

The melting point is 0 °C and the boiling point is 78 °C.