NextSDS Logo
Safety Data Sheet EN

METRYL PU CLEANER

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
METRYL PU CLEANER

Regulatory Identifiers

CAS Number
N/A

Manufacturers & Suppliers

B

Brenntag GmbH

national supplier

Stinnes-Platz 1, DE 45472 Muelheim

Emergency Contacts

Brenntag GmbH

+49 (0)208-7828-0

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Preparation consisting of the following components:

Chemical Name CAS Number Concentration Hazardous
Dimethyl adipate EC: 211-020-6 627-93-0 --- No
Dimethyl glutarate EC: 214-277-2 1119-40-0 --- No
Dimethyl succinate EC: 203-419-9 106-65-0 --- No
Propane-1,3-diol EC: 207-997-3 504-63-2 --- No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. If symptoms persist, call a physician.

Skin contact

Wash off immediately with soap and plenty of water. If skin irritation persists, call a physician.

Eye contact

Rinse thoroughly with plenty of water, also under the eyelids. If symptoms persist, call a physician.

Ingestion

Clean mouth with water and drink afterwards plenty of water. Do NOT induce vomiting. Call a physician immediately.

Immediate Medical Attention

Call a physician immediately.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.

Unsuitable media

High volume water jet

Specific hazards

Vapours may form explosive mixtures with air.

Firefighter Protection

In the event of fire, wear self-contained breathing apparatus. Wear appropriate body protection (full protective suit)

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protective equipment. Provide adequate ventilation. Keep away from heat and sources of ignition. Avoid contact with skin and eyes. Do not inhale gas/smoke/vapour/aerosol.

Environmental

Do not flush into surface water or sanitary sewer system. Avoid subsoil penetration. If the product contaminates rivers and lakes or drains inform respective authorities.

Cleanup methods

Absorb with liquid-binding material. Flush away traces with water.

Materials: sand, diatomite, acid binders, universal binders

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Keep container tightly closed. Provide sufficient air exchange and/or exhaust in work rooms.

Storage

Keep in a dry, cool and well-ventilated place. Keep only in the original container. Keep in an area equipped with solvent resistant flooring.

Fire prevention

Combustible Liquid. Keep away from sources of ignition - No smoking.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Refer to protective measures listed in sections 7 and 8.

Hands

Protective gloves; As the product is a preparation of several substances, the durability of the glove materials cannot be calculated in advance and has to be tested before use. Protective gloves should be replaced at first signs of wear.

Eyes

Tightly fitting safety goggles

Respiratory

In case of insufficient ventilation wear suitable respiratory equipment. Filter type A for gases and organic vapors.

Skin/Body

Protective work clothing

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
liquid, colourless
Colour
colourless
Colour Intensity
---
Form
liquid
Odor
sweet
Odor Threshold
---
Ph
---
Melting Point
---
Boiling Point
185 - 225 °C
Flash Point
103 °C
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
---
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
1,08 g/cm3
Flammability
---
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
---
Decomposition Temperature
---
Solubility
partly miscible
Partition Coefficient
---
Solubility In Water
partly miscible
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if stored and applied as directed.

Avoid

To avoid thermal decomposition, do not overheat.

Incompatible

Strong oxidizing agents; Acids

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Can be disposed of as a solid waste or burned in a suitable installation subject to local regulations.

Disposal

Disposal together with normal waste is not allowed. Do not let product enter drains.

Waste Codes

Waste codes should be assigned by the user based on the application for which the product was used. EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The product does not need to be labelled in accordance with EC directives or respective national laws.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for METRYL PU CLEANER?

The signal word is no signal word.

What is the physical form of METRYL PU CLEANER?

METRYL PU CLEANER is a liquid appearing as liquid, colourless with colourless color. It has sweet odor.

What is the solubility of METRYL PU CLEANER?

partly miscible