Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Suction system cleaner ZYME D conc. SSC300
- Product Code
- SSC300
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Cleaning agent, Cleaning material/ Detergent, SU20 Health services, PW Widespread use by professional workers
Manufacturers & Suppliers
PRISMAN GmbH
manufacturer
Otto Hahn Ring 6-18, D-64653 Lorsch, Germany
Emergency Contacts
Emergency Contact
++49 (0)6251 866980-0
Mo - Fr 8-18 Uhr
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Mixture of substances listed below with nonhazardous additions.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Propylene glycol | 57-55-6 | 10 - 25% | Yes |
For the wording of the listed hazard phrases refer to section 16.
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air; consult doctor in case of complaints.
Rinse opened eye for several minutes under running water. Then consult a doctor.
If symptoms persist consult doctor.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use fire extinguishing methods suitable to surrounding conditions.
No further relevant information available.
Firefighter Protection
No special measures required.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Not required.
Dilute with plenty of water. Do not allow to enter sewers/ surface or ground water.
Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust).
Materials: sand, diatomite, acid binders, universal binders, sawdust
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
No special measures required.
Store only in the original receptacle.
No special measures required.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No further data; see item 7.
Protective gloves. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Material of gloves: The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. Penetration time of glove material: The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed. For the permanent contact in work areas without heightened risk of injury (e.g. Laboratory) gloves made of the following material are suitable: Rubber gloves. For the permanent contact gloves made of the following materials are suitable: Neoprene gloves. As protection from splashes gloves made of the following materials are suitable: Butyl rubber, BR; Nitrile rubber, NBR.
Goggles recommended during refilling
Not required.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if used according to specifications.
No further relevant information available.
No dangerous reactions known.
No further relevant information available.
No further relevant information available.
No dangerous decomposition products known.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Smaller quantities can be disposed of with household waste.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- Void
- Shipping Name
- Void
- Transport Class
- Class Void
- Packing Group
- Void
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Suction system cleaner ZYME D conc. SSC300?
The signal word is no signal word.
What is the physical form of Suction system cleaner ZYME D conc. SSC300?
Suction system cleaner ZYME D conc. SSC300 is a fluid with according to product specification color. It has characteristic odor.
What is Suction system cleaner ZYME D conc. SSC300 used for?
Cleaning agent, Cleaning material/ Detergent, SU20 Health services, PW Widespread use by professional workers
What is the melting point of Suction system cleaner ZYME D conc. SSC300?
The melting point is Undetermined. and the boiling point is 100 °C.