NextSDS Logo
Ar

Armafinish 99

WARNING liquid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Armafinish 99

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Protective coat for insulation material based on synthetic rubber for outside installation and for making purposes for interior use.
Uses Advised Against
No data available.

Overview

Armafinish 99 is a liquid, white; grey substance commonly used protective coat for insulation material based on synthetic rubber for outside installation and for making purposes for interior use..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Warning)

Hazard Classifications

Aquatic Chronic Category 2 H411
Repr. Category 2 H361fd

GHS Hazard Pictograms & Safety Symbols

GHS08 GHS Hazard Pictogram: Serious health hazard - Carcinogenic, mutagenic, or toxic to organs

GHS08

GHS09 GHS Hazard Pictogram: Environmental hazard - Materials toxic to aquatic life and environment

GHS09

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H361fd: Suspected of damaging fertility. Suspected of damaging the unborn child.
  • H411: Toxic to aquatic life with long lasting effects.

Precautionary Statements

  • P201: Obtain special instructions before use.
  • P273: Avoid release to the environment.
  • P280: Wear protective gloves/eye protection.
  • P308+P313: IF exposed or concerned: Get medical advice/attention.
  • P391: Collect spillage.
  • P501: Dispose of contents/container to hazardous or special waste collection point.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Armacell GmbH

manufacturer

๐Ÿ“

Robert-Bosch-Strae 10 48153 Mnster

๐ŸŒ

DE

๐Ÿ“ž

+49 (0) 251 - 7603-200

๐Ÿ“ 

+49 (0) 251 - 7603-561

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Giftinformationszentrum Nord

๐Ÿ“ž

+49 (0)551 192 40

๐ŸŒ

DE

๐Ÿ—ฃ๏ธ

Languages: DE, EN

๐Ÿ’ก

For medical advice

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
tris(methylphenyl) phosphate
EC: 215-548-8
1330-78-5 5-10% โš ๏ธ Hazardous
1,2-benzisothiazol-3(2H)-one
EC: 220-120-9
2634-33-5 0.05% โš ๏ธ Hazardous

Composition Notes

Full Text for all H-phrases and EUH-phrases: pls. see section 16 (*,**,***,****) Detailed explanation pls. refer to CLP regulation No. 1272/2008, annex VI, 1.2

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

When inhaled remove to fresh air and seek medical aid.

๐Ÿ–๏ธ Skin Contact

When in contact with the skin, clean with soap and water.

๐Ÿ‘๏ธ Eye Contact

Remove contact lenses, irrigate copiously with clean, fresh water for at least 15 minutes, holding the eyelids apart and seek medical advice.

๐Ÿฝ๏ธ Ingestion/Swallowing

Do not induce vomiting. Call a doctor immediately.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
liquid, white; grey
๐ŸŽจ Colour
white; grey
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
liquid
๐Ÿ‘ƒ Odor
mild
๐Ÿ“Š Odor Threshold
No data available
๐Ÿงช Ph
No data available
๐ŸงŠ Melting Point
No data available
Critical Property
๐Ÿ’จ Boiling Point
No data available
Critical Property
๐Ÿ”ฅ Flash Point
- 101 C
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
No data available
๐Ÿ’จ Vapor Pressure
No data available
๐Ÿ“Š Vapor Density
No data available
๐Ÿ“Š Relative Density
No data available
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
appr. 1.33 g/cm R 4 at 20 C
Critical Property
๐Ÿ”ฅ Flammability
No data available
๐Ÿ“Š Upper Explosive Limit
No data available
๐Ÿ“Š Lower Explosive Limit
No data available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
No data available
๐Ÿ“Š Decomposition Temperature
No data available
๐Ÿ’ง Solubility
No data available
๐Ÿ“Š Partition Coefficient
No data available
๐Ÿ“Š Solubility In Water
No data available
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
7 mm/s at 40 C
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿงค Hand Protection

Sufficient protection is given wearing suitable protective gloves checked according to i.e. EN 374, in the event of risk of skin contact with the product. Before use, the protective gloves should be tested in any case for its specific work-station suitability (i.e. mechanical resistance, product compatibility and antistatic properties). Adhere to the manufacturers instructions and information relating to the use, storage, care and replacement of protective gloves. Protective gloves shall be replaced immediately when physically damaged or worn. Design operations thus to avoid permanent use of protective gloves. In case of short-term contact / splash protection: Appropriate Material nitrile rubber Material thickness 0.4 mm Breakthrough time < 30 min. Inappropriate material viton Material thickness 0.4 mm Breakthrough time - 30 min.

๐Ÿ‘๏ธ Eye Protection

Safety glasses with side protection shield (EN 166)

๐Ÿ˜ท Respiratory Protection

If workplace exposure limits are exceeded, a respiration protection approved for this particular job must be worn. In case of aerosol and mist formation, take appropriate measures for breathing protection in the event workplace threshold values are not specified.

๐Ÿฆบ Skin/Body Protection

Normal chemical work clothing.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

UN3082

๐Ÿ“ฆ Proper Shipping Name

ENVIRONMENTALLY HAZARDOUS SUBSTANCE, LIQUID, N.O.S.

โš ๏ธ Transport Hazard Class

9

๐Ÿ“‹ Packing Group

III

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Armafinish 99?

The signal word for this substance is "warning".

What is the physical form of Armafinish 99?

Armafinish 99 is a liquid appearing as liquid, white; grey with white; grey color. It has mild odor.

What is the solubility of Armafinish 99?

No data available

What is Armafinish 99 used for?

Protective coat for insulation material based on synthetic rubber for outside installation and for making purposes for interior use.

What are the hazard statements for Armafinish 99?

This substance has 2 hazard statements: H361fd: Suspected of damaging fertility. Suspected of damaging the unborn child. H411: Toxic to aquatic life with long lasting effects.

What is the melting point of Armafinish 99?

The melting point is No data available and the boiling point is No data available.