Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Loctite® PL® Premium Polyurethane Construction Adhesive
- Product Code
- 1390595
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
1-component-polyurethane adhesive
Uses advised against
None identified
Manufacturers & Suppliers
Henkel
manufacturer
+1 (860) 571-5100
http://www.henkelina.com
Emergency Contacts
Poison Control Center
1-877-671-4608
Poison Control Center
1-303-592-1711
CHEMTREC
1-800-424-9300
CHEMTREC
1-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Talc | 14807-96-6 | 30 - 60% | No |
| Methylenebis(phenylisocyanate) | 101-68-8 | 10 - 30% | No |
| Methylene bisphenyl isocyanate | 26447-40-5 | 1 - 5% | No |
| Hydrocarbon C11-25 dearomatized | 64742-46-7 | 1 - 5% | No |
| Polymeric diphenylmethane diisocyanate | 9016-87-9 | 1 - 5% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
If inhaled, immediately remove the affected person to fresh air.
Wash affected area immediately with soap and water. Remove contaminated clothes.
In case of contact with the eyes, rinse immediately with plenty of water for 15 minutes.
Do not induce vomiting. Rinse the mouth. Drink plenty of water.
Immediate Medical Attention
Immediate medical treatment necessary. If symptoms develop and persist, get medical attention. Seek immediate medical attention. Immediate medical advice necessary.
Medical Treatment
Treatment based on judgement of the physician in response to reactions of the patient.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water fog. Foam. Carbon dioxide.
Not available.
None known.
In case of fire, keep containers cool with water spray.
Firefighter Protection
Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Isolate the hazard area and deny entry to unnecessary and unprotected personnel.
Do not empty into drains / surface water / ground water.
Scrape up spilled material and place in a closed container for disposal.
Related Products
Similar products with comparable safety profiles
Loctite PL Premium Polyurethane Construction Adhesive
---
Loctite 2in1 Premium
---
Loctite® PL® Polyurethane Door, Window and Siding Sealant
---
Loctite® PL300® Foamboard Construction Adhesive
---
Loctite PL Polyurethane Roof and Flashing Sealant
---
Loctite PL500 Landscape Construction Adhesive
---
Loctite SuperBond
---
Loctite SuperBond
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with eyes, skin and clothing. Avoid extreme temperatures. Exposure to vapors of heated MDI can be extremely dangerous. Wash thoroughly after handling. Protect from moisture. Use only with adequate ventilation.
For safe storage, store between 15 °C (59°F) and 30 °C (86°F). Avoid moisture. Keep in a cool, well ventilated area away from heat, sparks and open flame. Keep container tightly closed until ready for use.
Wash thoroughly after handling.
Keep in a cool, well ventilated area away from heat, sparks and open flame.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions of storage and use.
Not available.
Contact with moisture, other materials that react with isocyanates, or temperatures above 350° F (177° C), may cause polymerization.
Avoid moisture. Keep away from open flames, hot surfaces and sources of ignition. Prolonged exposure to heat.
Oxidizing agents. Alcohols. Water.
Irritating and/or toxic fumes and gases may be emitted upon the product's decomposition. nitrogen oxides Aromatic isocyanates. carbon oxides.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Loctite® PL® Premium Polyurethane Construction Adhesive?
The signal word is danger.
What is the physical form of Loctite® PL® Premium Polyurethane Construction Adhesive?
Loctite® PL® Premium Polyurethane Construction Adhesive is a highly viscous, solid with tan color. It has mild odor.
What is the solubility of Loctite® PL® Premium Polyurethane Construction Adhesive?
Slightly soluble Water
What is Loctite® PL® Premium Polyurethane Construction Adhesive used for?
1-component-polyurethane adhesive
What are the hazard statements for Loctite® PL® Premium Polyurethane Construction Adhesive?
This substance has 6 hazard statements:
- H315: CAUSES SKIN IRRITATION.
- H317: MAY CAUSE AN ALLERGIC SKIN REACTION.
- H319: CAUSES SERIOUS EYE IRRITATION.
- H334: MAY CAUSE ALLERGY OR ASTHMA SYMPTOMS OR BREATHING DIFFICULTIES IF INHALED.
- H335: MAY CAUSE RESPIRATORY IRRITATION.
- H372: CAUSES DAMAGE TO ORGANS THROUGH PROLONGED OR REPEATED EXPOSURE.
What is the melting point of Loctite® PL® Premium Polyurethane Construction Adhesive?
The melting point is Not applicable and the boiling point is 172 - 341 °C (341.6 - 645.8 °F) no method / method unknown.