NextSDS Logo
SC

SCL-500

WARNING ciecz SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
SCL-500

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Przemysowe Profesjonalne Konsumenckie Pyn neutralizujcy do neutralizacji elektrolitycznych - pynw czyszczcych i odtuszczania powierzchni ze stali nierdzewnej.
Uses Advised Against
Nie uywaj do celw innych ni wymienione.

Overview

SCL-500 commonly used przemysowe profesjonalne konsumenckie pyn neutralizujcy do neutralizacji elektrolitycznych - pynw czyszczcych i odtuszczania powierzchni ze stali nierdzewnej..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Uwaga)

Hazard Classifications

Eye Irrit. Category 2 H319
Skin Irrit. Category 2 H315

GHS Hazard Pictograms & Safety Symbols

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H315: Dziaa dranico na skr.
  • H319: Dziaa dranico na oczy.

Precautionary Statements

  • P280: Stosowa rkawice ochronne / odzie ochronn / ochron oczu / ochron twarzy.
  • P337 + P313: W przypadku utrzymywania si dziaania dranicego na oczy: zasign porady / zgosi si pod opiek lekarza.
Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

Core Industrial B.V. company logo - Safety Data Sheet supplier organization

Core Industrial B.V.

manufacturer

Oud Camp 22, 3155 DL Maasland

NL

Liberta Consulting & Trading Roman ojek

importer

Ul. Podgrna 37 84-218 czyce

PL

+48 889881441

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

+31886972520

NL

W sprawie pilnych informacji zwrci si do

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
2-BUTOKSYETANOL
EC: 203-905-0
111-76-2 1-3% Hazardous
WODOROTLENEK SODOWY
EC: 215-185-5
1310-73-2 0.1-1% Hazardous

Composition Notes

Pene znaczenie symboli zagroenia (H) ujto w sekcji 16 karty.

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Wynie poszkodowanego na wiee powietrze, z daleka od miejsca wypadku. Jeeli poszkodowany nie oddycha, podj resuscytacj.

Skin Contact

Zdj zanieczyszczone ubranie. Natychmiast spuka skr pod prysznicem.

Eye Contact

Wyj soczewki kontaktowe, jeeli s. Natychmiast puka, przytrzymujc odchylone powieki, du iloci wody przez przynajmniej 30/60 minut.

Ingestion/Swallowing

Poda do picia jak nawikszej iloci wody. Wywoa wymioty tylko za wskazaniem lekarza.

Immediate Medical Attention Required

Natychmiast zasign porady lekarza.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Physical State
ciecz
Critical Property
Physical State Data
liquid
State Under Standard Conditions
Not available
Appearance
Not available
Colour
bezbarwny
Colour Intensity
Not available
Form
Not available
Odor
typowy
Odor Threshold
Niedostpne
Ph
10.9 (sol.1%)
Melting Point
Niedostpne
Critical Property
Boiling Point
100 C
Critical Property
Flash Point
nie palne
Critical Property
Freezing Point
Not available
Softening Point
Not available
Solidification Point
Not available
Cloud Point
Not available
Crystallisation Point
Not available
Relative Evaporation Rate
Not available
Evaporation Rate
Niedostpne
Vapor Pressure
Niedostpne
Vapor Density
Niedostpne
Relative Density
1 kg/dm3
Bulk Density
Not available
Density
Not available
Flammability
Niedostpne
Upper Explosive Limit
Niedostpne
Lower Explosive Limit
Niedostpne
Explosive Limits
Not available
Auto Ignition Temperature
Niedostpne
Decomposition Temperature
Niedostpne
Solubility
cakowicie rozpuszczalny w wodzie
Partition Coefficient
Niedostpne
Solubility In Water
Not available
Solubility In Fat
Not available
Molecular Weight
Not available
Voc Content
5.00 %
Metal Corrosion
Not available
Dynamic Viscosity
Not available
Kinematic Viscosity
Not available
Properties Status
Not available
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Należy zapewnić wydajną wentylację na stanowisku pracy stosując efektywną instalację wyciągową lokalną.

Hand Protection

Stosować rękawice ochronne kategorii III (p. norma EN 374). Wybór materiału z którego wytwarzane są rękawice ochronne zależny jest od: kompatybilność, degradacja, czas pęknięcia i przenikanie. W przypadku preparatów odporność rękawic ochronnych musi być przetestowana przed ich stosowaniem, bo ich wytrzymałość nie jest przewidywalna. Czas zużycia rękawic zależny jest od czasu i okoliczności użytkowania.

Eye Protection

Zaleca się stosować okulary ochronne w szczelnej obudowie (p. norma EN 166). Przewidzieć natrysk awaryjny z myjką do przepłukania oczu.

Respiratory Protection

W przypadku przekroczenia wartości granicznej (np. NDS-NDN) danej substancji lub jednej lub kilku substancji zawartych w produkcie, zaleca się stosować maskę z filtrem typu A, dobrą klasę (1, 2 lub 3) do ustalenia w zależności od dopuszczalnego stężenia użytkowego (p. norma EN 14387). W warunkach uwalniania się różnego rodzaju gazów lub par i/lub gazów lub par cząsteczkowych (aerozole, dymy, mgły, etc) należy przewidzieć filtry kombinowane. Środki ochrony dróg oddechowych należy stosować w przypadku gdy zastosowane środki techniczne nie są wystarczające do ochrony pracowników przed warunkami przekraczającymi wartości dopuszczalne. Należy zdawać sobie sprawę z faktu, że ochrona oferowana przez maski jest ograniczona w swojej skuteczności. Jeżeli rozpatrywana substancja uznawana jest za bezwonną lub wartości dopuszczalne NDS/NDN mają wartość niższą niż próg jej wykrywalności, a także w przypadku awarii, należy stosować sprzęt izolujący autonomiczny zasilany sprężonym powietrzem z otwartym obiegiem zgodnie z normą EN 137 lub sprzęt izolujący z doprowadzeniem czystego powietrza zgodnie z normą EN 138. Wybór stosownego środka ochronnego dróg oddechowych powinien być zgodny z normą EN 529.

Skin/Body Protection

Stosować odzież ochronną z długimi rękawami i obuwie ochronne dla celów profesjonalnych kategorii I zgodnie z rozporządzeniem II (p. Rozporządzenie 2016/425 i norma EN ISO 20344). Po zdjęciu odzieży ochronnej umyć powierzchnie ciała wodą i mydłem.

Environmental Exposure Controls

Należy wykonywać pomiary emisji wynikających z urządzeń wentylacyjnych i z procesów roboczych, zgodnie z rozporządzeniami w sprawie ochrony środowiska.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for SCL-500?

The signal word for this substance is "warning".

What is the physical form of SCL-500?

SCL-500 is a ciecz with bezbarwny color. It has typowy odor.

What is the solubility of SCL-500?

cakowicie rozpuszczalny w wodzie

What is SCL-500 used for?

Przemysowe Profesjonalne Konsumenckie Pyn neutralizujcy do neutralizacji elektrolitycznych - pynw czyszczcych i odtuszczania powierzchni ze stali nierdzewnej.

What are the hazard statements for SCL-500?

This substance has 2 hazard statements: H315: Dziaa dranico na skr. H319: Dziaa dranico na oczy.

What is the melting point of SCL-500?

The melting point is Niedostpne and the boiling point is 100 C.